Korisnički račun Kontakt
Vaša košarica
DPD i FedEx – datum dostave na stranici proizvoda
Trebate pomoć? Pitajte našeg AI asistenta

InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m

InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m
InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m
InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m
InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m
InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m
InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m
11,25 €
PDF
PDF
Dostupnost 98 Šifra proizvoda 1429520 Model 88201 Jamstvo 2 godine

Dostava i povrat

Očekivana dostava utorak, 1. prosinca
Naš detaljni sustav za praćenje pošiljaka redovito će Vas obavještavati o statusu
Mogućnosti plaćanja
Platna karticaVisaMastercardPayPalApple PayGoogle PayBankovna uplata

Postavite pitanje – AI asistent odgovara odmah.

Opis

InLine fiber optical simplex cable LC/APC to LC/APC OS2 9/125µm, length 1 m, is a single-mode patch cable designed for indoor FTTH and single-channel links. It features LC connectors with 8° APC polish on both ends and OS2 grade fiber with a 9/125 µm core/cladding. The cable is intended for reliable, low-loss connections between the household fiber entry point, optical modem or transceiver and other fiber equipment.

Advantages

The cable provides low insertion loss and high return loss consistent with single-mode OS2 performance, enabling stable transmission for broadband and telecom applications. Its 3.0 mm outer diameter, halogen-free sheath and stainless steel spiral reinforcement increase mechanical stability compared with very thin provider-supplied pigtails. The neutral white sheath allows unobtrusive installation in living areas. A test report is supplied to document optical performance.

Suitable for

  • FTTH indoor patching between fiber entry point and optical modem
  • Connecting single-mode transceivers and ONT/OLT devices
  • Short single-channel links and fiber terminations inside premises

Key specifications

  • Connector type: LC to LC, APC 8° polished
  • Fiber type: Single-mode OS2, 9/125 µm
  • Cable outer diameter: approx. 3.0 mm
  • Construction: armoured/flexible metal tubing with stainless steel spiral reinforcement
  • Sheath: halogen-free, neutral white
  • Typical insertion loss: <0.20 dB
  • Maximum insertion loss (specified): <0.30 dB
  • Return loss: >60 dB
  • Operating temperature range: -40 °C to +85 °C
  • Length: 1 m

How to use

Connect one LC/APC connector to the fiber outlet or patch panel and the other LC/APC connector to the optical modem, transceiver or receiver. Ensure connectors are clean before mating to avoid contamination-related loss; use appropriate dust caps when the cable is not connected. Route the cable with gentle bends, observing the minimum bend radius of the fiber, and secure it in place using clips or cable management suitable for indoor installations.

Recommendations

For consistent optical performance, clean connectors with a fiber cleaning tool before each connection and avoid sharp bends or crushing. Use the supplied test report to verify insertion and return loss if required during installation or maintenance.

How to use

Connect one LC/APC connector to the fiber outlet or patch panel and the other LC/APC connector to the optical modem, transceiver or receiver. Ensure connectors are clean before mating to avoid contamination-related loss; use appropriate dust caps when the cable is not connected. Route the cable with gentle bends, observing the minimum bend radius of the fiber, and secure it in place using clips or cable management suitable for indoor installations.

Recommendations

For consistent optical performance, clean connectors with a fiber cleaning tool before each connection and avoid sharp bends or crushing. Use the supplied test report to verify insertion and return loss if required during installation or maintenance.

Ključne značajke
  • Halogen free outer Jacket
  • Armoured Cable OD: 3.0mm±0.2mm
  • flexible metal tubing one core
  • Fiber: OS2 9/125µm - single Mode
  • I-VH-2E,G.652.D
  • APC 8° Polished
  • IL<0.30dB,RL>60dB
  • IL(typical)<0.20dB
  • with test report
  • Conform IEC 610304-2 IEC60332-3-1 IEC60754-2 IEC 61754-20
  • Operating Temperature: -40 to +85°C
  • Storage Temperature: -40 to +85°C
  • OS2
  • 1 m
  • LC Male
  • LC Male
  • Connector polish type: APC
  • Single-mode
  • White

Specifikacije

Specifikacije
Boja proizvoda
Bijela
Dimenzije (ŠxVxD)
150 x 1000 x 10 mm
Dubina pakiranja
160 mm
Duljina kabela
1 m
Gubitak umetanja
0.3 dB
Konektor 2
LC
Potpuni dupleks
Ne
Povratni gubitak
60 dB
Priključak 1
LC
Promjer jezgre
9 µm
Promjer kabela
3 mm
Promjer plašta
125 µm
Radna temperatura (T-T)
-40 - 85 °C
Širina pakiranja
150 mm
Spol konektora 1
Muški
Spol konektora 2
Muški
Struktura modova vlakna
Jednomodni
Temperatura skladištenja (T-T)
-40 - 85 °C
Testni protokol u kompletu
Da
Težina
16 g
Težina pakiranja
24 g
Visina pakiranja
10 mm
Volumen paketa
300 cm³
Vrsta optičkog vlakna
OS2
Vrsta poliranja konektora
APC

Letak

Otvori Letak
Povijest cijene u posljednjih 6 mjeseci
InLine optički simplex kabel, FTTH, LC/APC8° na LC/APC8° 9/125µm OS2 1m
Trenutačna cijena
11,25 €
Najniža cijena 7 d.
8,58 €
Najviša cijena 7 d.
11,25 €
Promjena 24 h
0,00 €   0%
Promjena 7 d.
+2,67 €   +31%
Promjena 30 d.
+2,58 €   +30%

Napiši recenziju

Ocjena *
Napomena: HTML se ne prevodi!

Ista serija i alternative

12

Popularni proizvodi u ovoj kategoriji

7
Prodavatelj: UAB KUR LT · Gariūnų g. 57-14, LT-02300 Vilnius, Litva · Matični broj 303192950 · PDV ID LT100008198612 · Isporuka iz EU-a (Litva)
WhatsApp
Messenger
Pozdrav, ja sam AI asistent DistriNodea. Mogu Vam pomoći pronaći proizvode, usporediti mogućnosti, izraditi ponude u PDF formatu ili otvoriti zahtjev za podršku.
Sve kategorije