Korisnički račun Kontakt
Vaša košarica
DPD i FedEx – datum dostave na stranici proizvoda
Trebate pomoć? Pitajte našeg AI asistenta

Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m

Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m
Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m
Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m
Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m
Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m
Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m
11,73 €
PDF
PDF
Dostupnost 19 Šifra proizvoda 1429519 Model 88402 Jamstvo 2 godine

Dostava i povrat

Očekivana dostava utorak, 1. prosinca
Naš detaljni sustav za praćenje pošiljaka redovito će Vas obavještavati o statusu
Mogućnosti plaćanja
Platna karticaVisaMastercardPayPalApple PayGoogle PayBankovna uplata

Postavite pitanje – AI asistent odgovara odmah.

Opis

Single-fiber simplex patch cable InLine LC/APC (8°) to SC/APC (8°) 9/125µm OS2, 2 m is a pre-assembled single-mode duplex replacement cable designed for FTTH and point-to-point optical connections. The cable uses OS2 9/125 µm fibre and features an LC/APC connector on one end and an SC/APC connector on the other, both with 8° APC polish for low back-reflection. The armoured 3.0 mm outer sheath and internal stainless steel spiral tube provide mechanical protection suitable for in-home routing between the house transfer point, ONT/OLT and fibre modem.

Advantages

The cable combines a compact LC form factor with the robust SC interface to allow flexible device and patch-panel connections while keeping insertion loss low and return loss high. Its halogen-free outer jacket and reinforced metal tubing increase durability compared with thin factory-supplied jumpers, reducing the risk of breakage during installation or everyday use. The product is delivered with test report data and complies with relevant IEC standards for fibre performance and fire/toxicity behaviour.

Suitable for

  • FTTH installations linking the home entry point to ONT/ONT ports or home routers
  • Patch panel to network equipment connections in premises and small data closets
  • Single-mode optical links requiring APC-terminated connectors to minimise back-reflection
  • Replacement of thin or damaged pre-installed consumer fibre jumpers

Key specifications

  • Fibre type: OS2 single-mode, 9/125 µm
  • Connectors: LC/APC (8°) to SC/APC (8°)
  • Cable outer diameter: approx. 3.0 mm (armoured)
  • Internal reinforcement: stainless steel spiral tube
  • Insertion loss (typical): <0.20 dB; maximum <0.30 dB
  • Return loss: >60 dB (APC)
  • Polish type: APC 8°
  • Operating temperature range: -40 °C to +85 °C
  • Sheath: halogen-free, white
  • Cable length: 2 m

How to use

Connect the LC/APC end to the device or patch panel port sized for LC connectors and the SC/APC end to the corresponding SC port. Ensure both connector ferrules and device ports are clean before mating to avoid performance degradation; use a fibre-cleaning tool or lint-free swabs with appropriate cleaner. Route the cable without sharp bends and avoid compressing the armoured tube; maintain the minimum bend radius recommended for single-mode jumper cables. Verify link quality after installation using the supplied test report or appropriate optical test equipment.

Recommendations

Store and install the cable in a dry environment, avoid exposure to prolonged UV light or chemicals. When replacing existing consumer jumpers, choose this sturdier 3 mm armoured cable to reduce the likelihood of damage during handling. For best optical performance, use APC-terminated connectors throughout the link where optical reflections must be minimised, and perform post-installation insertion loss and return loss checks if network equipment supports them.

How to use

Connect the LC/APC end to the device or patch panel port sized for LC connectors and the SC/APC end to the corresponding SC port. Ensure both connector ferrules and device ports are clean before mating to avoid performance degradation; use a fibre-cleaning tool or lint-free swabs with appropriate cleaner. Route the cable without sharp bends and avoid compressing the armoured tube; maintain the minimum bend radius recommended for single-mode jumper cables. Verify link quality after installation using the supplied test report or appropriate optical test equipment.

Recommendations

Store and install the cable in a dry environment, avoid exposure to prolonged UV light or chemicals. When replacing existing consumer jumpers, choose this sturdier 3 mm armoured cable to reduce the likelihood of damage during handling. For best optical performance, use APC-terminated connectors throughout the link where optical reflections must be minimised, and perform post-installation insertion loss and return loss checks if network equipment supports them.

Ključne značajke
  • Halogen free outer Jacket
  • Armoured Cable OD:3.0mm±0.2mm
  • flexible metal tubing one core
  • Fiber: OS2 9/125µm - single Mode
  • I-VH-2E,G.652.D
  • APC 8° Polished
  • IL<0.30dB,RL>60dB
  • IL(typical)<0.20dB
  • with test report
  • Conform IEC 610304-2 IEC60332-3-1 IEC60754-2 IEC 61754-20
  • Operating Temperature: -40 to +85°C
  • Storage Temperature: -40 to +85°C
  • OS2
  • 2 m
  • LC Male
  • SC Male
  • Connector polish type: APC
  • Single-mode
  • White

Specifikacije

Specifikacije
Boja proizvoda
Bijela
Dimenzije (ŠxVxD)
170 x 2000 x 8 mm
Dubina pakiranja
170 mm
Duljina kabela
2 m
Konektor 2
SC
Potpuni dupleks
Ne
Priključak 1
LC
Promjer jezgre
9 µm
Promjer kabela
3 mm
Promjer plašta
125 µm
Radna temperatura (T-T)
-40 - 85 °C
Širina pakiranja
165 mm
Spol konektora 1
Muški
Spol konektora 2
Muški
Struktura modova vlakna
Jednomodni
Temperatura skladištenja (T-T)
-40 - 85 °C
Testni protokol u kompletu
Da
Težina
34 g
Težina pakiranja
41 g
Visina pakiranja
80 mm
Volumen paketa
2300 cm³
Vrsta optičkog vlakna
OS2
Vrsta poliranja konektora
APC

Letak

Otvori Letak
Povijest cijene u posljednjih 6 mjeseci
Optički simplex patch kabel InLine LC/APC (8°) na SC/APC (8°) 9/125 µm OS2, 2 m
Trenutačna cijena
11,73 €
Najniža cijena 7 d.
9,44 €
Najviša cijena 7 d.
11,73 €
Promjena 24 h
0,00 €   0%
Promjena 7 d.
+2,29 €   +24%
Promjena 30 d.
+2,20 €   +23%

Napiši recenziju

Ocjena *
Napomena: HTML se ne prevodi!

Više INLINE proizvoda u ovoj kategoriji

12

Popularni proizvodi u ovoj kategoriji

7
Prodavatelj: UAB KUR LT · Gariūnų g. 57-17, LT-02300 Vilnius, Litva · Matični broj 303192950 · PDV ID LT100008198612 · Isporuka iz EU-a (Litva)
WhatsApp
Messenger
Pozdrav, ja sam AI asistent DistriNodea. Mogu Vam pomoći pronaći proizvode, usporediti mogućnosti, izraditi ponude u PDF formatu ili otvoriti zahtjev za podršku.
Sve kategorije